ERROR CODE: F10
ERROR TYPE: Insufficient water circulation error
PROBABLE CAUSE: Installation congestion
SOLUTION:
1- The pump connection cables may be loose or displaced or lost their conductivity. Check the connections. If there is a problem, replace the cables and reset the device.
2- Ensure that the pump is working properly. If there is a problem, replace the pump.
3- Check if there is congestion in the installation.
4- There may be congestion in the heat exchanger's water line. In this case, clean the heat exchanger.
5- If there is no congestion in the installation, ensure that all radiator valves are on or at least one of them is on. If it is open, there may be congestion on the boiler's internal bypass line. In this case, clean the
3-way valve assembly and replace it if necessary.
Updated on 9 January 2024, Tuesday